Description

In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges.  The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.

Key facts

Published
23 Oct 2026
Last changed
28 Oct 2026
Assigned by
CERT-PL
EPSS
0.263% likely to be exploited in the next 30 days, higher than 18.327% of CVEs (scores for 17 Nov 2026)
SSVC (CISA)
Exploitation: none; Automatable: no; Technical impact: total

Severity scores

Each score is shown as its source gave it. They are not averaged or merged.

  • 9.0CVSS 4.0, Criticalfrom the CNA (CERT-PL)CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Historical context and remediation

This reference retains the original CVE publication date. A recent record update does not mean a new attack occurred.

No separately sourced impact summary is available on this page yet. Consult the description, version data and dated exploitation evidence.

No explicit remediation statement is available on this page yet. Consult the original record and vendor references before choosing a fix.

Version statuses below come from the CNA. An “unaffected” version is not necessarily a currently supported release or proof of a patch date. EPSS is a dated risk estimate, not a count of historical attacks.

Read the original CVE record.

Affected products

VendorProductVersions
CGMCGM CLININET
  • Default status: unknown
  • 0 up to and including 2026.MS3 (affected)

Timeline

  1. 23 Oct 2026 Published

Weakness