CVE-2026-111731

Infinite loop when reading PDPortDataCheck record of subslot 0

  • High 8.7

Description

P-Net before 1.0.3 enters an infinite loop when handling a read request for the PDPortDataCheck record with subslot 0 (whole module). The loop over the ports never advanced to the next port, so the request never completes and the device stops responding. A remote unauthenticated attacker can use this to cause a denial of service.

Key facts

Published
29 Oct 2026
Last changed
5 Nov 2026
Assigned by
rt-labs
EPSS
0.402% likely to be exploited in the next 30 days, higher than 34.995% of CVEs (scores for 16 Nov 2026)
SSVC (CISA)
Exploitation: none; Automatable: yes; Technical impact: partial

Severity scores

Each score is shown as its source gave it. They are not averaged or merged.

  • 8.7CVSS 4.0, Highfrom the CNA (rt-labs)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

What to do

  • Upgrade to P-Net 1.0.3 or later.CNA solution statement

Historical context and remediation

This reference retains the original CVE publication date. A recent record update does not mean a new attack occurred.

No separately sourced impact summary is available on this page yet. Consult the description, version data and dated exploitation evidence.

Version statuses below come from the CNA. An “unaffected” version is not necessarily a currently supported release or proof of a patch date. EPSS is a dated risk estimate, not a count of historical attacks.

Read the original CVE record.

Affected products

VendorProductVersions
RT-LabsP-Net
  • Default status: unaffected
  • 0 up to but excluding 1.0.3 (affected)

Timeline

  1. 29 Oct 2026 Published

Weakness

References