CVE-2026-118052

Module Manager loaders leave the manager mutex held when a module preamble's sizes overflow, blocking every later module operation

  • Medium 6.8

Description

In Eclipse ThreadX versions 6.0.1 through 6.5.2.202603, the Module Manager loaders return an overflow error without releasing the Module Manager mutex when a module preamble declares a data or stack size that overflows the allocation arithmetic. Loading such an image blocks every later module load, start, stop and unload from other threads until the system is reset.

Key facts

Published
2 Nov 2026
Last changed
2 Nov 2026
Assigned by
eclipse
EPSS
0.112% likely to be exploited in the next 30 days, higher than 1.393% of CVEs (scores for 16 Nov 2026)
SSVC (CISA)
Exploitation: none; Automatable: no; Technical impact: partial

Severity scores

Each score is shown as its source gave it. They are not averaged or merged.

  • 6.8CVSS 4.0, Mediumfrom the CNA (eclipse)CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

Historical context and remediation

This reference retains the original CVE publication date. A recent record update does not mean a new attack occurred.

No separately sourced impact summary is available on this page yet. Consult the description, version data and dated exploitation evidence.

No explicit remediation statement is available on this page yet. Consult the original record and vendor references before choosing a fix.

Version statuses below come from the CNA. An “unaffected” version is not necessarily a currently supported release or proof of a patch date. EPSS is a dated risk estimate, not a count of historical attacks.

Read the original CVE record.

Affected products

VendorProductVersions
Eclipse FoundationEclipse ThreadX
  • Default status: unaffected
  • 6.0.1 up to and including 6.5.2.202603 (affected)

Timeline

  1. 2 Nov 2026 Published

Weakness

References