Description

A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.

Key facts

Published
13 Oct 2026
Last changed
14 Oct 2026
Assigned by
siemens
EPSS
0.107% likely to be exploited in the next 30 days, higher than 1.164% of CVEs (scores for 18 Nov 2026)
SSVC (CISA)
Exploitation: none; Automatable: no; Technical impact: total

Severity scores

Each score is shown as its source gave it. They are not averaged or merged.

  • 7.7CVSS 3.1, Highfrom the CNA (siemens)CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
  • 8.4CVSS 4.0, Highfrom the CNA (siemens)CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Historical context and remediation

This reference retains the original CVE publication date. A recent record update does not mean a new attack occurred.

No separately sourced impact summary is available on this page yet. Consult the description, version data and dated exploitation evidence.

No explicit remediation statement is available on this page yet. Consult the original record and vendor references before choosing a fix.

Version statuses below come from the CNA. An “unaffected” version is not necessarily a currently supported release or proof of a patch date. EPSS is a dated risk estimate, not a count of historical attacks.

Read the original CVE record.

Affected products

VendorProductVersions
SiemensSIMATIC IPC BX-21A
  • Default status: unknown
  • 0 up to but excluding V31.01.13 (affected)
SiemensSIMATIC IPC RW-543A
  • Default status: unknown
  • 0 up to but excluding V1.1.4 (affected)
SiemensSIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G
  • Default status: unknown
  • 0 up to but excluding V28.01.15 (affected)